ASTM D6096-2007 工作温度90°C的电线和电缆用聚氯乙烯绝缘性的标准规范
作者:标准资料网
时间:2024-05-17 14:23:48
浏览:8419
来源:标准资料网
下载地址: 点击此处下载
【英文标准名称】:StandardSpecificationforPoly(VinylChloride)InsulationforWireandCable,90176;COperation
【原文标准名称】:工作温度90°C的电线和电缆用聚氯乙烯绝缘性的标准规范
【标准号】:ASTMD6096-2007
【标准状态】:现行
【国别】:
【发布日期】:2007
【实施或试行日期】:
【发布单位】:美国材料与试验协会(US-ASTM)
【起草单位】:D09.18
【标准类型】:(Specification)
【标准水平】:()
【中文主题词】:电缆绝缘;电绝缘;绝缘;塑料工艺;聚氯乙烯
【英文主题词】:acceleratedwaterabsorption;acvoltagetest;dcvoltagetest;insulationresistance;poly(vinylchloride)insulation;90Cpoly(vinylchloride)insulation;thickness
【摘要】:1.1Thisspecificationcoversathermoplasticinsulationofpoly(vinylchloride)orthecopolymerofvinylchlorideandvinylacetate.Thisinsulationisrecommendedforuseatconductortemperaturesnotinexcessof90C.1.2Dependingonthethicknessoftheinsulation,themaximumvoltageused,andwhetherthelocationiswetordry,thisinsulationisacceptableforusein300V(dry)and600V(wetordry)powerandcontrolcircuits.1.3Thisinsulationhaspotentiallow-temperatureinstallationlimitations.Consultthemanufacturerforspecificrecommendationsforinstallation.1.4Whenevertwosetsofvaluesarepresented,indifferentunits,thevaluesinthefirstsetarethestandard,whilethoseinparenthesesareforinformationonly.1.5Inmanyinstancestheinsulationmaterialcannotbetestedunlessithasbeenformedaroundaconductororcable.Therefore,testsaredoneoninsulatedwireorcableinthisspecificationsolelytodeterminetherelevantpropertyoftheinsulationmaterialandnottotesttheconductororcompletedcable.
【中国标准分类号】:K15
【国际标准分类号】:29_035_20
【页数】:3P.;A4
【正文语种】:
【原文标准名称】:工作温度90°C的电线和电缆用聚氯乙烯绝缘性的标准规范
【标准号】:ASTMD6096-2007
【标准状态】:现行
【国别】:
【发布日期】:2007
【实施或试行日期】:
【发布单位】:美国材料与试验协会(US-ASTM)
【起草单位】:D09.18
【标准类型】:(Specification)
【标准水平】:()
【中文主题词】:电缆绝缘;电绝缘;绝缘;塑料工艺;聚氯乙烯
【英文主题词】:acceleratedwaterabsorption;acvoltagetest;dcvoltagetest;insulationresistance;poly(vinylchloride)insulation;90Cpoly(vinylchloride)insulation;thickness
【摘要】:1.1Thisspecificationcoversathermoplasticinsulationofpoly(vinylchloride)orthecopolymerofvinylchlorideandvinylacetate.Thisinsulationisrecommendedforuseatconductortemperaturesnotinexcessof90C.1.2Dependingonthethicknessoftheinsulation,themaximumvoltageused,andwhetherthelocationiswetordry,thisinsulationisacceptableforusein300V(dry)and600V(wetordry)powerandcontrolcircuits.1.3Thisinsulationhaspotentiallow-temperatureinstallationlimitations.Consultthemanufacturerforspecificrecommendationsforinstallation.1.4Whenevertwosetsofvaluesarepresented,indifferentunits,thevaluesinthefirstsetarethestandard,whilethoseinparenthesesareforinformationonly.1.5Inmanyinstancestheinsulationmaterialcannotbetestedunlessithasbeenformedaroundaconductororcable.Therefore,testsaredoneoninsulatedwireorcableinthisspecificationsolelytodeterminetherelevantpropertyoftheinsulationmaterialandnottotesttheconductororcompletedcable.
【中国标准分类号】:K15
【国际标准分类号】:29_035_20
【页数】:3P.;A4
【正文语种】:
下载地址:
点击此处下载